I90-IN90-I90F-IN90-F

Indicators with gravity and fixed reaction, with counter
These indicators have to be fitted in motion handwheels to measure adjustments (angles, shiftings, speed, etc.) on a control dial, with a regulation screw on the cover front. They are assembled by pressing them directly into the handwheel seat.
  • Technopolymer or metal case. Transparent and shock-proof polycarbonate cover. Protection IP64. Max. temperature: 80°C.
  • I90-I90F: the dial measure is given by the two pointers: the red pointer carries out a complete turn at every rotation of the drive shaft, and at the same time, the black pointer makes a rotation fraction.The turns that the black pointer needs to carry out to complete a rotation is the ratio of the indicator.
  • IN90-IN90F with analogue-digital indication. The measures reading is ensured by a 5-digit counter (red digits to indicate decimals) and by a graduated control dial. The pointer carries out a complete turn at every rotation of the drive shaft and reads the decimal values.
  • The indicators I90 and IN90 are suitable for horizontal or slightly inclined shafts. Available with handwheels P125P, P150P, P175P, P200P.
  • The indicators I90F and IN90F are mounted on shafts with any position. Supplied with handwheels P125FP, P150FP, P175FP, P200FP.

 
          PART                           
          Positioning screw                   Gears for fixed reaction

Photogallery

I90

 

I90F

 


ASSEMBLING
Fix the handwheel on the drive shaft, then with a pressure assemble the indicator by pressing it inside the handwheel. Zero set the measure with the screw.
Concerning the fixed reaction indicator, bear in mind that the lock pin is adjusted on zero at 12 hour. Carry out the assembling as described and fix the pin with a bracket.

Access to Reserved Area

Did you forget your password?


Richiedi l'accesso




*Required replies

I90 IN90 I90F IN90F IT  EN  DE 
Click here to download >

I90 IN90 I90F IN90F IT  FR  ES 
Click here to download >

TYPE REDUCTION RATIO DIAL SCALE INDICATION AFTER 1 REVOLUTION DIAL SCALE

I90-I90F

2:1

0-6

I90-I90F

4:1

0-6

I90-I90F

6:1

0-6

I90-IN90F

10:1

0-10

I90-I90F

12:1

0-12

I90-I90F

20:1

0-20; 10-0-10; 20-0-20

I90-I90F

24:1

0-24; 0-25

I90-I90F

30:1

0-30

I90-I90F

36:1

0-36

I90-I90F

40:1

0-40; 0-50

I90-I90F

60:1

0-60; 0-80

I90-I90F

100:1

0-100

I90-I90F

120:1

0-100

I90-I90F

200:1

0-100

IN90-IN90F

0000 1

0-10; 100 DIVISIONS

IN90-IN90F

0000 2

0-20; 100 DIVISIONS

IN90-IN90F

0000 4

0-40; 100 DIVISIONS

IN90-IN90F

0000 5

0-50; 100 DIVISIONS

IN90-IN90F

0000 6

0-60; 100 DIVISIONS

IN90-IN90F

0000 8

0-80; 100 DIVISIONS

IN90-IN90F

0001 0

0-100; 100 DIVISIONS

IN90-IN90F

0001 5

0-15; 100 DIVISIONS

IN90-IN90F

0002 0

0-20; 100 DIVISIONS

IN90-IN90F

0002 5

0-25; 100 DIVISIONS

IN90-IN90F

0003 0

0-30; 100 DIVISIONS

IN90-IN90F

0004 0

0-40; 100 DIVISIONS

IN90-IN90F

0005 0

0-50; 100 DIVISIONS

IN90-IN90F

0006 0

0-60; 100 DIVISIONS